sales@evoluxfiber.com    +86-755-28169892
Cont

Have any Questions?

+86-755-28169892

Telecom fiber optic components manufacturer and OEM supplier

Evolux Telecom Network Fiber Optic Solution for Central Offices, Transmission Links and Radio Sites

Source the pigtails, patch cords, adapters and fixed attenuators your network needs from Evolux. We confirm the connector, polish and fiber grade against your specification first, then prepare samples before bulk production.

 

Send Your Network Requirement  See Recommended Products

A sales representative will contact you within 24 hours.

Telecom network fiber optic components for an outdoor cabinet and a transmission rack

Since 2013

Founded in Shenzhen, with OEM and ODM supply for project buyers

6 Product Families

Connectors, adapters, pigtails, patch cords, PLC splitters and terminal boxes

FC, SC, LC, ST, E2000

UPC or APC polish, single-mode or multimode

Sample to Bulk

Sample orders, small-batch customization and bulk production

 

Fiber Optic Components That Keep a Telecom Network Compatible at Every Connection

 

Many of the problems a telecom buyer needs to prevent start at a connection point. A patch cord arrives with the wrong polish, the frame is built on FC or E2000 while the new equipment ships with LC, or a receiver is overdriven because nobody ordered the attenuator. Our telecom network fiber optic solution is built around those points, with connectors, adapters, pigtails, patch cords, fixed attenuators and PLC splitters for ODF systems, equipment patching, fiber distribution and outdoor radio links.

 

Whether you buy for a telecom operator, a network contractor, a system integrator or a distribution business, the sections below take you from a network position to a specific Evolux product, let you check its published figures, and show what to send for a quotation. For PON access distribution, see the FTTH ODN Solution. For MPO/MTP trunks and high-density LC cabling, see the Data Center Fiber Cabling Solution.

  • ODF and cross-connect
  • Mixed connector interfaces
  • Power control and testing
  • FTTA radio sites

Telecom Fiber Optic Products Grouped by Where They Sit in Your Network

 

Every figure below comes from that product's own page, so you can check it against your specification before you ask for a quote. Loss grade, jacket and length vary by configuration, and we confirm them on the quotation.

 

ODF Termination and Cross-Connect

 

Evolux fiber optic pigtails terminate the incoming fibers at the distribution frame, and our single-mode patch cords connect ODF ports to the transmission equipment.

12-core pigtail bundle with blue SC/UPC connectors and yellow fibers

SC/UPC 12-Core Single-Mode Pigtail

 

  • 12 fibers, each terminated with an SC/UPC connector
  • 9/125 µm single-mode in 0.9 mm PVC or LSZH
  • Insertion loss ≤0.3 dB

View Specifications

Yellow single-mode patch cable with threaded metal FC connectors

FC/UPC Single-Mode Simplex Patch Cable

 

  • 9/125 µm fiber in a 2.0 mm yellow PVC jacket
  • Insertion loss ≤0.20 dB and return loss ≥50 dB
  • 1310/1550 nm

View Specifications

Yellow duplex patch cord with blue LC/UPC connectors

LC to LC Single-Mode Duplex Patch Cord

 

  • Insertion loss ≤0.30 dB (IEC Grade C) or ≤0.15 dB (IEC Grade B)
  • Return loss ≥50 dB with UPC polish
  • 0.9, 2.0 or 3.0 mm in PVC, LSZH or OFNP

View Specifications

Hybrid Patch Cords and Adapters for Mixed Connector Interfaces

 

When the equipment port and the distribution frame use different connector families, a hybrid patch cord or a male-to-female adapter joins the two without re-terminating the frame.

Single-mode pigtail with a green E2000 APC connector

E2000 APC Single-Mode Pigtail

 

  • E2000/LSH connector with a dust-proof cover
  • G652D / OS2 9/125 fiber, simplex
  • 1 m length in 0.9 mm PVC with a 30 mm minimum bend radius

View Specifications

Simplex patch cable with a blue LC connector and a green E2000 connector

LC to E2000 Simplex Patch Cable

 

  • LC with 1.25 mm ferrule on one end and E2000 on the other
  • Insertion loss ≤0.3 dB
  • Single-mode and multimode versions

View Specifications

Hybrid adapter with a blue LC plug and a metal FC socket

LC Male to FC Female Hybrid Adapter

 

  • LC/UPC plug to FC/UPC socket for 9/125 µm single-mode
  • Insertion loss ≤0.3 dB typical and ≤0.5 dB maximum
  • Panel-mount or free-hanging, rated for more than 1,000 matings

View Specifications

Fixed Attenuators and Test Accessories for Power Control and Monitoring

 

Our fixed optical attenuators set the level at a bulkhead or an equipment port, while bare fiber adapters and FBG reflectors support OTDR testing and link verification.

Female-to-female FC fixed attenuator with a metal body and a red dust cap

FC/UPC Female Fixed Attenuator for DWDM Links

 

  • Fixed values from 1 dB to 30 dB
  • Accuracy ±0.5 dB up to 9 dB and ±10% from 10 dB
  • 1260–1620 nm with 300 mW maximum input power

View Specifications

Green LC/APC fixed attenuator marked 5 dB

LC/APC Fixed Attenuator for PON and CATV

 

  • 8° APC polish on 9/125 µm single-mode
  • 1–30 dB with return loss ≥65 dB
  • 1260–1360 nm and 1460–1580 nm

View Specifications

Bare fiber adapter with an FC ferrule and a square metal clamp body

FC/UPC Bare Fiber Adapter for OTDR Testing

 

  • Accepts 250 µm and 900 µm fiber
  • Insertion loss ≤0.2 dB typical
  • More than 1,000 mating cycles from −40 °C to +85 °C

View Specifications

Fiber Bragg grating reflector in a green SC/APC plug-style housing

FBG Reflector for OTDR Link Checks

 

  • Passes 1260–1625 nm and reflects 1645–1655 nm (or 1620–1630 nm)
  • Pass-band insertion loss ≤1.0 dB (Premium) or ≤1.5 dB (Standard)
  • SC or LC in UPC or APC

View Specifications

Outdoor Waterproof Patch Cords for FTTA Radio Sites

 

Sealed, armored assemblies for the part of the network that has no cabinet around it, such as the BBU-to-RRU run on a tower.

Black armored outdoor patch cord with sealed waterproof connectors

IP67 or IP68 Outdoor Patch Cord for FTTA

 

  • Sealed connectors on armored cable
  • PDLC, ODVA, FullAXS, ODC or LC/SC/FC/ST interfaces
  • 0.3 m to 500 m, rated −40 °C to +70 °C

View Specifications

Black outdoor cable with metal ODC connectors and chained dust caps

ODC Outdoor Waterproof Patch Cable

 

  • ODC male or female in 2-core or 4-core, sealed to IP68
  • Single-mode (G.657A) or multimode
  • More than 1,000 mating cycles from −40 °C to +85 °C

View Specifications

Can't see your connector pairing, fiber count or length?

Tell us what each end mates with and Evolux will match the parts from the full range, as a standard item or a custom fiber optic assembly.

Ask for a Matching Product

You can also browse every connector, adapter and attenuator, pigtail, patch cord, PLC splitter and terminal box we supply.

 

How to Choose Fiber Optic Components for a Telecom Network Project

 

Start from the connection point rather than a generic cable list. Work out what each end mates with, then fix the polish, the fiber grade and the physical build for that position.

 

Your situation What usually fits Confirm before the RFQ Where to look
ODF Fiber Termination A pigtail bundle fusion-spliced to the incoming trunk or feeder cable Connector and polish, fiber grade, fibers per bundle, buffer diameter, pigtail length SC/UPC 12-core pigtail, or other SC, LC, FC, ST and E2000 pigtails
ODF to Equipment Cross-Connect A single-mode simplex or duplex patch cord matched to both ports Connector at each end, UPC or APC, length, jacket material, insertion-loss grade FC/UPC simplex patch cable or LC to LC duplex patch cord
Mixed Connector Families A hybrid patch cord, or a male-to-female hybrid adapter at the panel, when the equipment and the frame use different interfaces Both interfaces, polish on each side, panel-mount or free-hanging use LC to E2000 patch cable or LC male to FC female adapter
Power Control on DWDM, CATV or PON A fixed attenuator at the bulkhead or the equipment port, where channel power has to be reduced or equalized Attenuation value, wavelength window, maximum input power, connector and polish FC/UPC female attenuator or LC/APC attenuator
Acceptance Testing and Fault Location A reusable bare fiber adapter on the OTDR or power meter, and an FBG reflector at the ONU end for checks from the central office Instrument port type, fiber coating diameter, OTDR test wavelength band Bare fiber adapter and FBG reflector
FTTA and Unsheltered Links A sealed, armored outdoor patch cord built to the radio-port interface Outdoor connector type, IP rating, fiber count, length, jacket, burial, duct or aerial installation Outdoor waterproof patch cord or ODC patch cable
PON Access Distribution PLC splitters and terminal boxes sized to the split plan beyond the central office Split ratio, splitter package, connector type, box capacity, indoor or outdoor mounting PLC splitters, terminal boxes and the FTTH ODN Solution

 

The connector you order should always follow the equipment port, the frame and the project specification. Send the port schedule with your RFQ and we will check compatibility before anything goes into production.

 

Why Telecom Contractors and Distributors Buy Fiber Optic Components From Evolux

 

A telecom fiber optic supplier is only useful when what arrives on site matches the drawing. Here is how we work to make that happen, and what it saves your team.

Operators at assembly benches in the Evolux workshop
Assembly workshop
Technician assembling yellow single-mode fiber cable and connectors at a workbench
Cable and connector assembly
Workers sorting and bagging fiber optic components before packing
Component sorting and packaging

One Supplier Across Six Passive Product Families

Connectors, adapters, pigtails, patch cords, PLC splitters and terminal boxes can sit on a single BOM. That means fewer vendors to qualify and one specification review instead of several.

Your Specification Is Confirmed Before Production

We confirm the specification first, verify a sample where needed, and test the finished product against the agreed requirements. Labeling and packaging are kept consistent for repeat orders.

Published Loss Figures You Can Put in a Budget

Insertion loss and return loss are stated product by product. Where an assembly comes in more than one grade, such as IEC Grade B or Grade C for the LC duplex patch cord, you choose the grade and it goes on the order line.

Legacy and Outdoor Interfaces on the Same Order

FC and E2000 for existing frames, LC for new equipment, hybrid adapters between them, and PDLC or ODC connectors for radio sites. You do not need a second source for the less common parts.

OEM Labels and Packaging for Your Brand

As an OEM supplier of fiber optic patch cords and pigtails, Evolux lets distributors and project buyers specify jacket and boot colors, product labels, cable markers and neutral or customer-specific packaging.

Sample, Small Batch or Bulk

Order samples for compatibility testing, a small customized batch for a pilot site, or bulk production for a network rollout or wholesale stock. The approved sample becomes the reference for the order.

Engineering Checks Before You Approve a Telecom Fiber BOM

 

These points are worth settling on the approved BOM or drawing before any samples are made.

Check 01

Interface and Polish at Every Mated Pair

List the connector family and polish on both sides of each adapter. Published return loss differs by polish, for example ≥50 dB for the FC/UPC patch cable and ≥65 dB for the LC/APC attenuator, and UPC and APC end faces should never be mated to each other. Our guide to PC, UPC and APC polish explains why.

Check 02

Fiber Grade Rather Than Just Single-Mode

Write the grade and the core and cladding size on the BOM. The E2000 pigtail is specified as G652D / OS2 9/125 and the outdoor assemblies as G.657A, so each line can be checked against your requirement.

Check 03

Connection Loss Budget

Add the published insertion loss of every connectorized part in the path, then fiber attenuation and margin. If a tighter budget calls for the ≤0.15 dB grade instead of ≤0.30 dB on LC duplex patch cords, say so in the RFQ.

Check 04

Attenuation Value and Input Power

Fixed attenuators are ordered by dB value. Check the tolerance and the power rating against the position. The FC/UPC female model is rated to 300 mW, and the LC/APC model is listed from 125 mW to 300 mW depending on the version.

Check 05

Environment and Jacket

For indoor frames, name PVC, LSZH or OFNP as the project requires. For outdoor links, name the ingress rating and temperature range. The outdoor waterproof patch cord is published as IP67 or IP68 from −40 °C to +70 °C.

Check 06

Test Records With the Shipment

Depending on the product, testing may cover insertion loss, return loss and end-face inspection. Define the wavelength, limits and sampling basis in the order so the report matches your acceptance procedure.

Custom and OEM Telecom Fiber Optic Assemblies From Sample to Bulk Order

 

Evolux builds custom fiber optic patch cords, pigtails and attenuators for telecom projects on top of its catalog configurations, from a single sample to a bulk order.

What to Include in Your RFQ

Treat the catalog version as the starting point and list each change you need. A complete request shortens clarification and makes sample testing meaningful.

Request a Project Quote

1

Application and network position: ODF termination, equipment patching, power control, test kit or outdoor radio link.

2

Interfaces: connector type at each end, UPC or APC polish, simplex, duplex or fiber count.

3

Optical requirements: fiber grade, wavelength, insertion-loss and return-loss limits, attenuation values.

4

Mechanical build: length, cable diameter, jacket material, armor and ingress rating where relevant.

5

Commercial details: quantity per configuration, sample quantity, labels, packaging and required documents.

SC, LC, FC, ST, MPO/MTP and hybrid fiber optic connector options

Options You Can Configure

 

  • Connector type, including SC, LC, FC, ST, MPO/MTP and hybrid combinations
  • UPC or APC polish, single-mode or multimode fiber
  • Standard or custom length in simplex, duplex or armored cable
  • Jacket and boot colors, product labels and cable markers
  • Neutral or customer-specific packaging

How an Order Moves From Sample to Shipment

Four steps from your first message to delivery.

Share the Application

Tell us where the parts go and we confirm the technical requirements with you.

01

Get a Recommendation

We recommend standard products or a custom configuration for your project.

02

Evaluate Samples

You test samples for compatibility and performance before committing.

03

Approve Bulk Production

We arrange production, inspection, packaging and shipment to your order.

04

Standards and Test Records Behind These Telecom Fiber Components

 

Quality evidence is most useful when it is tied to the exact product and batch. The statements below appear on the named product pages, and you can ask Evolux for the supporting document that covers the model you are quoted.

Telcordia GR-910-CORE and GR-1221-CORE

Both are listed as compliance for the FC/UPC female fixed attenuator, and GR-910-CORE is also listed for the LC/APC attenuator. Ask for the test report that covers the dB values you are ordering.

RoHS Material Compliance

Stated for both fixed attenuators and for the FC/UPC bare fiber adapter. For procurement records, request a current declaration that names the quoted product.

IEC Insertion-Loss Grades

The LC to LC single-mode duplex patch cord is published at ≤0.30 dB for IEC Grade C and ≤0.15 dB for IEC Grade B. The grade is a purchasing choice and belongs on the order line.

IP67 and IP68 Ingress Ratings

Published for the outdoor waterproof patch cord and for the ODC patch cable, which is listed as IP68. Confirm which rating applies to the connector type and cable you select.

Inspection at Four Stages

Production passes through incoming quality control, in-process control, optical and mechanical testing, and final inspection before shipment. Test items are set by product model and the agreed specification.

Documents Your Tender Requires

Certificate numbers and operator approvals are not published on these product pages. List every document your tender calls for in the RFQ so each can be confirmed in writing before approval.

Telecom Network Fiber Optic Solution FAQ for Buyers and Engineers

Is Evolux a manufacturer or a trading supplier of telecom fiber optic components?

Shenzhen Evolux Fiber Co., Ltd. is a fiber optic components manufacturer founded in 2013. The head office is in Shenzhen and the company lists a factory address in Baise, Guangxi. Telecom buyers can order catalog products, request samples, or send a project BOM for a custom or OEM quotation.

Which fiber optic products does a telecom network project usually need?

It depends on the network position. ODF termination uses pigtails and adapters, cross-connects and equipment links use single-mode patch cords, and mixed connector environments add hybrid patch cords or hybrid adapters. Amplified, CATV and PON links may need fixed attenuators, and radio sites need sealed outdoor patch cords. All of these can be supplied individually or combined into one project BOM.

Should we specify FC, SC, LC or E2000 connectors?

Specify the connector already fitted to the equipment port and the distribution frame, because the installed hardware fixes the interface. FC uses a threaded coupling, while SC and LC use push-pull latching. Where two families meet, use a hybrid patch cord or a male-to-female hybrid adapter. Our FC connector selection guide covers the FC case in more detail.

When does a telecom link need APC polish instead of UPC?

Follow the polish of the ports you are mating with and never mix the two on one connection. On our product pages, UPC assemblies are published at return loss ≥50 dB and the LC/APC attenuator at ≥65 dB, which is why APC is offered for reflection-sensitive PON and CATV links. If your port schedule shows both, list the polish per position on the BOM.

How do we choose a fixed optical attenuator value?

Work out the level reduction needed at the receiver, then order the nearest fixed value. The FC/UPC female attenuator is available from 1 dB to 30 dB, with ±0.5 dB accuracy from 1 to 9 dB and ±10% from 10 to 30 dB. The LC/APC attenuator lists standard values of 2, 4, 5, 6, 10, 15, 20, 25 and 30 dB. Include the wavelength window and the maximum optical power at that port in your RFQ.

What are the MOQ, sample policy and lead time for bulk telecom fiber optic orders?

There is no single MOQ or lead time for every product, because configuration and quantity affect the order. As a reference, the E2000 pigtail page lists a minimum order quantity of 100 pieces. Sample orders, small-batch customization and bulk production are all supported. Send the quantity per configuration and your required delivery date, and you will receive terms for your BOM.

Can Evolux supply OEM or private-label fiber optic products with test reports?

Yes. OEM and ODM supply covers connector types, cable lengths, jacket and boot colors, product labels, cable markers and neutral or customer-specific packaging. Datasheets and IL/RL test reports are listed among the project support items. Tell us the label text, the report format and whether results are needed per unit or per batch.

 

Related Fiber Optic Solutions and Selection Guides

Send Your Telecom Fiber BOM to Evolux for a Matched Quotation

 

Tell us the network position, the connector and polish at each end, the fiber grade, lengths, attenuation values, quantities and labeling plan. Whether you need standard telecom fiber optic components or an OEM configuration, our team will check the parts against your specification and recommend matching products. A sales representative will contact you within 24 hours.

 

Send Project Requirements  Email Our Sales Team

 

Reach the Evolux Sales Team Directly