sales@evoluxfiber.com    +86-755-28169892
Cont

Have any Questions?

+86-755-28169892

Evolux Fiber Optic LC Connectors for High-Density Networks
video
Evolux Fiber Optic LC Connectors for High-Density Networks

Evolux Fiber Optic LC Connectors for High-Density Networks

Factory-direct supply for single-mode and multimode links, in UPC or APC polish, for 0.9, 2.0 and 3.0 mm cable. Rated at ≤0.3 dB insertion loss and supplied wholesale or as OEM/ODM parts by Evolux, an LC connector manufacturer in Shenzhen.
Send Inquiry

Product Introduction

Fiber Optic LC Connector Specifications and Configurations

 

These are the rated figures for every LC fiber connector in the range, laid out the way engineers check them against a link budget.

 

Evolux single-mode LC UPC connector with blue housing and boot
Parameter Specification
Connector type LC, small form factor with 1.25 mm ceramic ferrule
Polish type UPC / APC
Fiber mode Single-mode / Multimode
Cable OD 0.9 mm / 2.0 mm / 3.0 mm
Insertion loss ≤0.3 dB
Return loss ≥50 dB
Insert-pull test 1,000 cycles, ≤0.3 dB
Operating temperature -40 °C to +75 °C
Housing colour Green / Blue / Beige
Application FTTx, CATV, Metro, LAN
Used in Patch cords, PLC splitters, pigtails

 

Choose your LC configuration by mode, polish and cable OD

 

Most RFQs come down to three choices. Housing colours follow the common industry code, so each version is easy to tell apart in the warehouse and on the rack.

 

Configuration Housing Cable OD Where buyers usually specify it
Single-mode LC/UPC ● Blue 0.9 / 2.0 / 3.0 mm Data centre, LAN and Metro links
Single-mode LC/APC ● Green 0.9 / 2.0 / 3.0 mm FTTH splitter outputs, CATV, pigtails
Multimode LC/UPC ● Beige 0.9 / 2.0 / 3.0 mm Premises distribution and short-reach LAN

Know your mode, polish, cable OD and quantity?

That is all we need to price wholesale Evolux LC connectors, with free samples to check before you commit.

Send My Configuration

 

Why Network Buyers Order Our Wholesale LC Fiber Connectors

 

Four design features that change project cost and installation time, each tied to a figure you can verify on samples.

 

Twice the ports per panel

Half the size of an SC connector, so shelves and outlets hold double the fibers.

What it saves you: fewer enclosures and rack units per build, which lowers system cost before the first cable is pulled.

 
 

Polarized for correct Tx and Rx

The connector seats in one orientation only, so transmit and receive stay where the designer put them, connection after connection.

What it saves you: fewer swapped-fiber faults at commissioning.

 
 

Anti-snag latch

Resists catching on neighbouring cords and still holds loss at ≤0.3 dB after 1,000 insert-pull cycles.

What it saves you: less rework from accidental unplugging during moves, adds and changes.

 
 

No field polishing

Crews plug in pre-terminated assemblies instead of fitting field-mountable connectors on site.

What it saves you: shorter installation windows on FTTH and LAN rollouts.

 

 

How Our Precision LC Optical Connector Is Built from Ferrule to Latch

 

Single-mode LC APC optical connector with green housing for 0.9 mm fiber

Four details decide whether an LC optical connector keeps its loss figures after installation, not just on the test bench.

Pre-radiused, free-floating ceramic ferrule

The pre-radiused end face and floating mount let the ferrule self-align under spring pressure. Physical contact stays consistent, which is what keeps insertion loss at ≤0.3 dB from one batch to the next.

One-piece, pull-proof body

Cable tension is isolated from the ferrule, so a tug on the cord does not break optical contact or raise back reflection in a live link.

Precision anti-rotation key

The ferrule cannot turn inside the adapter. On APC versions this keeps the angled end faces matched, which is how low reflection is maintained in FTTH and CATV links.

Corrosion-resistant housing for -40 °C to +75 °C

The body is built for outdoor cabinets and unconditioned distribution boxes as well as climate-controlled data halls.

 

Project-Ready LC Connectors for Data Centre, FTTH and CATV Builds

 

Each application below shows the configuration buyers usually specify for it, so you can match the part to the project before you ask for a quote.

Planning the whole network rather than one part? See our data centre fiber cabling solution and FTTH ODN solution.

Multimode LC fiber connector with beige housing for premises cabling

 

Data centre cabling

Dense patch panels and cross-connects where doubling ports per rack unit saves floor space.

Typical spec: SM or MM, UPC

Telecom networks

LAN, MAN and WAN links that need low, repeatable loss at every mated pair.

Typical spec: SM, UPC

FTTH and FTTx access

PLC splitter outputs and pigtails in distribution boxes, where low back reflection protects the PON signal.

Typical spec: SM, APC

CATV networks

Video and RF-over-fiber links, where reflections show up as degraded signal quality.

Typical spec: SM, APC

Data processing networks

Server and storage links that depend on polarized connections to keep Tx and Rx orientation fixed.

Typical spec: SM or MM, UPC

Premises distribution

Building backbones and wall outlets, where the compact footprint fits more fibers into each faceplate.

Typical spec: MM, UPC

 

Custom LC Connectors Built to Your OEM Part Number

 

Distributors, cable assembly shops and network brands use our OEM LC connectors to sell under their own name or to feed their own production lines. You define the part, and we build, mark and pack it to that definition.

Fill in the fields below and you have a complete part specification. A dedicated support team then looks after your Evolux OEM LC connector account, so sample approval, production and reorders all go through one contact.

Details of our private-label programme are on the OEM/ODM fiber optic product solution page.

Custom LC connectors in five housing and boot colours for OEM orders

 

Field Your options
Fiber mode Single-mode or multimode
Polish UPC or APC
Cable OD 0.9, 2.0 or 3.0 mm
Housing and boot colour Green, blue and beige as standard; other colours, such as the aqua and magenta shown above, to match your scheme
Boot style Choose from our range of boot styles
Branding Custom branding for your private label
Packaging Pack count, labels and cartons to your specification
Quantity Flexible, from trial lots to volume runs

Send My OEM Spec to Evolux

 

Five Checkpoints Behind Every Factory-Tested LC Connector Shipment

 

Our quality system is ISO 9001:2015 certified. Within it, each order passes five inspection points before it leaves the factory.

 

Material inspection

Ferrules, housings and boots are checked before they reach the line.

01

Production monitoring

In-process checks stop defects at the stage where they start.

02

Performance testing

Insertion loss and return loss are verified against the ≤0.3 dB and ≥50 dB limits.

03

Final inspection

Finished connectors are checked before they are released for packing.

04

Packaging inspection

Pack counts, labels and protection are confirmed before cartons are sealed.

05

 

Bulk LC Connector Orders Packed and Labelled the Way Your Warehouse Needs

 

Loose connectors are easy to mix up once the cartons are opened. Bulk orders are packed to your requirements, and every carton goes through our packaging inspection before dispatch. Include your destination and preferred incoterm in the RFQ, and the shipping method is confirmed together with the quote.

Pack count set by you

Your label format and carton marking

Each configuration packed separately

Separate labels for APC and UPC parts

Packaging inspected before sealing

Shipping method confirmed with the quote

 

MOQ, Lead Times and Sample Terms for Fiber Optic LC Connectors

 

Item Terms
Minimum order Flexible order quantities; tell us your volume and we quote it
Standard lead time 5–7 business days for regular orders
Large or customised orders Lead time confirmed with your quote
Samples Free samples for testing
Payment T/T, L/C, PayPal

 

Qualifying Evolux as Your Factory-Direct LC Connector Supplier

 

Evolux is a fiber optic LC connector manufacturer and OEM supplier in Shenzhen, China, developing, producing and distributing passive fiber products since 2013. Instead of a company profile, here are straight answers to the questions sourcing and quality teams ask before approving a new connector source.

 

What your team checks Our answer
Quality system ISO 9001:2015 certified
Incoming material control Ferrules, housings and boots inspected before production
Optical performance ≤0.3 dB insertion loss, ≥50 dB return loss, ≤0.3 dB after 1,000 insert-pull cycles
Proof before purchase Free samples so your lab can test the parts first
Standard lead time 5–7 business days on regular orders
Engineering support In-house technical team for configuration and application questions
Private label Custom branding and packaging, with a dedicated support team
Related products Adapters, pigtails, patch cords, PLC splitters and terminal boxes from the same company
Payment terms T/T, L/C, PayPal

 

Working with lower-density panels as well? Compare with our SC connector, or read more about our company.

Approving a new LC connector source?

Start with free samples built to your mode, polish and cable OD, and test them in your own lab before any volume order.

Request Evolux LC Connector Samples

 

Fiber Optic LC Connector Questions from Procurement Teams

Q: How fast can you ship a wholesale LC connector order?

A: Regular orders ship on a standard lead time of 5 to 7 business days. Evolux, as a factory-direct LC connector manufacturer, confirms the lead time for large or customised orders together with the quote.

Q: Can we test free LC connector samples before placing a bulk order?

A: Yes. Samples are free, so your lab can check insertion loss, return loss and fit before you commit to volume. State the mode, polish and cable OD so the samples match the parts you plan to order.

Q: Should we order LC/UPC or LC/APC connectors?

A: Specify LC/APC (green) where back reflection has to be kept to a minimum, such as PLC splitter outputs in FTTH and CATV links. LC/UPC (blue for single-mode, beige for multimode) is the usual choice for data centre, LAN and Metro links. Both polishes are available for 0.9, 2.0 and 3.0 mm cable.

Q: Do you make private-label LC connectors for distributors?

A: Yes. Evolux, as an OEM LC connector supplier, offers custom branding, packaging to your specification, a choice of boot styles and colours, and a dedicated support team for your account.

Q: Can we place a small trial order before volume production?

A: Yes. Order quantities are flexible, so you can start with free samples, move to a trial lot for qualification, and scale once your team approves the parts.

Q: How do you keep LC connector quality consistent from batch to batch?

A: Production at the Evolux LC connector factory runs under an ISO 9001:2015 certified quality system with five checkpoints: incoming material, production monitoring, performance testing, final product inspection and packaging inspection. Performance testing verifies insertion loss of 0.3 dB or less and return loss of 50 dB or more.

 

Request a Quote from Evolux, Your LC Connector Manufacturer

Give us the configuration and quantity, and tell us if you want free samples first. Your request goes straight to the Evolux sales team.

Mode and polish  |  Cable OD  |  Quantity  |  Branding or packaging needs

Submit to Evolux

Prefer email? Write to sales@evoluxfiber.com

 

Hot Tags: Evolux Fiber Optic LC Connectors for High-Density Networks, China Evolux Fiber Optic LC Connectors for High-Density Networks manufacturers, suppliers, factory, fiber optic connector for fiber optic sensors, fiber optic connector for fiber optic boxes, fiber optic connector for fiber optic archives, fiber optic connector for fiber optic cartons, fiber optic connector for fiber optic isolating optical cables, fiber optic connector for fiber optic ip addresses

Send Inquiry

(0/10)

clearall