Fiber Optic Patch Cord SC APC TO LC UPC Simplex Black

Fiber Optic Patch Cord SC APC TO LC UPC Simplex Black

Fiber Optic Patch Cord SC APC TO LC UPC Simplex Black
●Low insertion loss, high return loss
●Small, light, high dense connection
●The standard exact plastic material
●High credibility and stability
●Good in repeatability and ex-changeability
Send Inquiry

Product Introduction

What is SC LC patch cable?

 

SC-LC fiber optic patch cord is a small compact patch cable very popularly used in many applications. These network solutions include telecommunication networks, LANs, data processing networks, device terminations and premises distributions. SC-LC patch cords are designed to deliver fast Ethernet solutions in Gigabit applications and ATM applications with less space consumption.

 

Specification

 

 

Parameter Unit FC, SC, LC/ Armoured fiber patch cord ST, MU MT-RJ, MPO E2000
SM MM SM MM SM MM SM
PC UPC APC PC PC UPC PC PC UPC PC PC APC
Insertion loss(typical) dB ≤0.3 ≤0.2 ≤0.3 ≤0.2 ≤0.3 ≤0.2 ≤0.2 ≤0.3 ≤0.2 ≤0.2 ≤0.3 ≤0.3
Return loss dB ≥45 ≥50 ≥60 ≥30 ≥45 ≥50 ≥30 ≥45 ≥50 ≥35 ≥55 ≥75
Operating wavelength nm 1310, 1510 1310, 1510 1310, 1510 1310, 1510
Exchangeability dB ≤0.2 ≤0.2 ≤0.2 ≤0.2
Vibration dB ≤0.2 ≤0.2 ≤0.2 ≤0.2
Operating temperature -40~75 -40~75 -40~75 -40~75
Storage temperature -45~85 -45~85 -45~85 -45~85
Cable diameter mm φ3.0, φ2.0, φ0.9 φ3.0, φ2.0, φ0.9 φ3.0, φ2.0, φ0.9 φ3.0, φ2.0, φ0.9

 

 

 

SC/APC to LC/UPC Fiber Optic Patch Cord

 

APC-to-UPC Hybrid Design

 

SC/APC 8° angled polish provides ≥60 dB return loss. LC/UPC dome polish provides ≥50 dB. One cable connects both interface types - green body identifies APC, blue identifies UPC.

SC APC to LC UPC fiber optic patch cord singlemode OS2 simplex yellow

LCAPC

 

Small Form Factor, High-Density LC Connection

 

LC 1.25 mm ferrule is half the size of SC 2.5 mm - doubles port density in SFP/SFP+/QSFP transceivers. RJ-style latch for fast plug-and-pull operation.

G.657.A1 Bend-Insensitive Fiber

 

10 mm minimum bend radius for tight routing in patch panels and under-floor wiring. Backward compatible with G.652.D. Supports up to 40 km at 1550 nm.

G.657.A1 bend insensitive fiber patch cord 10mm bend radius test

 

 

Application Solutions

 

Typical deployment scenarios for this SC to LC singlemode fiber patch cable.

FTTH GPON network OLT to ONT topology

FTTH / GPON Access Network

Connects SC/APC OLT ports to LC/UPC ONT equipment at the ODF. The PLC splitter in the distribution path also uses SC/APC interfaces.

Data center rack with LC patch panel and SFP transceivers

Data Center Cross-Connect

Patches SC/APC fiber distribution panels directly to LC/UPC SFP+ transceivers in ToR switches. Supports 10GbE, 25GbE, and 100GbE.

CATV headend optical transmitter equipment

CATV / RF over Fiber

APC end-face prevents CSO/CTB distortion in analog video. Used between headend transmitters and optical nodes in HFC networks.

OTDR test equipment connected to fiber distribution frame

Telecom Testing & Measurement

Reference-grade test cord for connecting LC/UPC OTDR test ports to SC/APC distribution frames in central offices.

Enterprise network room with SC and LC fiber equipment

Enterprise LAN Migration

Bridges legacy SC-terminated structured cabling to new LC-based switches and routers without re-termination.

CWDM DWDM mux demux equipment panel

WDM Multiplexing Systems

Interfaces SC/APC mux/demux ports with LC/UPC transponders in CWDM and DWDM deployments.

 

Products Description

 

Every fiber optic patch cord is 100% tested for insertion loss and return loss at 1310/1550 nm. Zirconia ceramic ferrules deliver ≤0.2 dB exchangeability through ≥1,000 mating cycles. ISO 9001:2015 certified facility. Telcordia GR-326, IEC 61300, RoHS, REACH compliant. OFNR and LSZH jacket options. Cable diameter φ0.9 / φ2.0 / φ3.0 mm. Custom lengths 0.3 m–100 m available.

product-1-1

 

 

 

Products Description

 

 

Q: What is the difference between APC and UPC on a fiber optic patch cord?

A: APC has an 8° angled end-face (≥60 dB return loss), UPC has a dome-shaped end-face (≥50 dB). GPON and CATV systems require APC at the distribution side; equipment ports like SFP transceivers use UPC. Green connector = APC, Blue = UPC.

Q: Can I plug an APC connector into a UPC adapter?

A: No. Mismatched polish creates an air gap causing >3 dB loss and ferrule damage. Always mate APC to APC, UPC to UPC. The angled key slot on SC/APC adapters prevents most accidental cross-mating.

Q: What speeds and distances are supported?

A: 100 Mbps to 100GbE. Up to 10 km at 1310 nm, 40 km at 1550 nm. Actual reach depends on transceiver optical budget and total link loss.

Q: What is the difference between a patch cord and a fiber pigtail?

A: A patch cord has connectors on both ends for plug-and-play use. A pigtail has one connector and one bare fiber end for fusion splicing to trunk cables.

Q: Can I order custom lengths or duplex versions?

A: Yes. Custom 0.3 m–100 m, lead time 3–5 days. Duplex, armored, and LSZH versions available. We also make 12-core SC/APC to LC/UPC for higher fiber count needs.

 

 

Hot Tags: fiber optic patch cord sc apc to lc upc simplex black, China fiber optic patch cord sc apc to lc upc simplex black manufacturers, suppliers, factory, fiber optic patch cord for telecommunication, simplex fiber optic patch cord, fiber optic patch cord with e2000 connector, fiber optic transmission cord, fiber optic patch cable, fiber optic patch cord for lan